Change Location
   Home > Service > Fluid/Filter Change Intervals
 

For the model you requested

Transmission Allison Electric Drives™ EP 40/50 Systems™
Fluid Type  100% TranSynd® fluid.
Allison Transmission requires the following change intervals
Transmission Fluid 100,000 miles
(160 000 km)
48 months
,
whichever comes first.
Main Filter 50,000 miles
(80 000 km)
24 months
,
whichever comes first.
Internal Filter Overhaul
Lube/Auxiliary Filter
If replacing a
Non High-Capacity Filter
50,000 miles
80 000 km
24 months
,
whichever comes first.
If replacing a
High-Capacity Filter
100,000 miles
160 000 km
48 months
,
whichever comes first.
NOTES

NOTE: An initial 5,000-mile filter change interval is required for all New, ReTran®, and Overhauled transmissions. For more information, refer to the Initial Filter Change Interval Recommendation Chart.


Extended filter change intervals are only valid with the use of Allison Transmission high-capacity filters. For specific Allison Part Numbers, refer to Service Tip #1099.


Local conditions, severity of operation or duty cycle may require more or less frequent fluid change intervals that differ from the published recommended fluid change intervals of Allison Transmission.


Change fluid/filters after recommended mileage, months elapsed, or hours in operation, whichever occurs first.


Transmission protection and fluid change intervals can be optimized by the use of fluid analysis. Filters must be changed at or before recommended intervals.