Allison Transmission > Service > Electronic Tools
Introduction
 
Table Of Contents
Introduction
Purchase DOC
Requirements
Translator Devices
Support
Updates

Electronic Tools

Latest Diagnostic Tool Releases

 Universal Allison DOC® v11.1

The Universal Allison DOC® For PC-Service Tool V11.1 update was made available in May of 2013, as a “no charge” internet-download for all the Universal Allison DOC® V11.0.x users. Universal Allison DOC® For PC-Service Tool represents a single package containing each of the former variations of Allison DOC® including Allison DOC® For PC – Service Tool, Allison DOC® For PC – H 40/50 EP, Allison DOC® For Fleets – (1000/2000 Series™), and Allison DOC® For Fleets – (3000/4000 Series™). Separate license keys are required to activate each of these components. Some of the new features and enhancements included within the Universal Allison DOC® For PC-Service Tool V11.1 update are:

Allison DOC® For PC:

  • Adds Throttle Position Sensor Voltage to 1000/2000 Data Monitor parameter list
  • Adds updated Advanced Help videos
  • Adds feature to save 5th Gen Reprogramming Configuration files
  • This includes current I/O, CMC, Active Package and TCM Password selection
  • This does not include protected parameter changes
  • Adds messages to provide rules associated with 5th Gen protected parameters that a technician is Reprogramming
  • Allison DOC® For PC (H 40/50 EP):

    Includes the following MY13 specific updates:

    • New parameter displayed in DC/DC Converter section in Data Monitor and ESS Data Monitor DC/DC Converter ON/OFF Command
    • New High Voltage Distribution Module (HVDM) category in Data Monitor and ESS Data Monitor
    • CH1 and CH2 Voltage, Current, Temperature
    • CH1 and CH2 Enabled, Pre-Charging, Contractor, Open Pending, Ready and Fault Status States
    • New Heating-Ventilation-Air Conditioning (HVAC) category in Data Monitor and ESS Data Monitor
    • HVAC Main Switch ON/OFF Command

    Note: ‘HVAC Main Switch ON/OFF Command’ can have around a 10 second delay due to the transmit rate on that message

    • HVAC Inverter ON/OFF Enable
    • HVAC High Voltage Permissive
    • New Output Tests
    • HVDM Master Discrete Enable
    • High Voltage Accessory CH1 Discrete Enable
    • High Voltage Accessory CH2 Discrete Enable
    • Addition Of New High Voltage Distribution Module (HVDM) DTCs

 

 Universal Allison DOC® v11.0.1

 The Universal Allison DOC® For PC-Service Tool V11.0.1 update was made available in January of 2013. Universal Allison DOC® For PC-Service Tool represents a single package containing each of the former variations of Allison DOC® including Allison DOC® For PC – Service Tool, Allison DOC® For PC – H 40/50 EP, Allison DOC® For Fleets – (1000/2000 Series™), and Allison DOC® For Fleets – (3000/4000 Series™). Separate license keys are required to activate each of these components. Universal Allison DOC® For PC-Service Tool V11.0.1 will be available by DVD, USB thumb drive, or downloaded file through the Allison Web Store (https://allison.noregon.com).  Some of the new features and enhancements included within the Universal Allison DOC® For PC-Service Tool V11.0.1 update are:

  • Adds support for 1000, 2000, 3000, 4000 Series Product Allison 5th Generation controllers
    • When manually connecting to 5th Gen controller, choose CAN protocol
  • Adds the Troubleshooting Manuals for 1000, 2000, 3000, 4000 Series Product Allison 5th Generation Controls
  • Includes a Technician’s Library under the Help menu
    • Includes reference documents including Input / Output guides
  • Ability to reprogram certain 5th Gen Customer Modifiable Constants (CMCs) that previously required a new calibration
    • These CMCs are password controlled and can be unlocked by the Allison Calibration Desk
    • See the Protected Parameter list in Section 41 of the Allison DOC® for PC–Service Tool User Guide for a complete list of these parameters

 Please note that Windows® Vista® is not compatible with the Softing CANusb and the V5.10 Softing Driver is not compatible with the CANusb.

Please contact Noregon Systems at 1-877-659-6913 (US/Canada) or 1-336-970-5534 (International) for more information or E-mail: support@noregon.com.  To place an order, visit the Allison Web Store:  https://allison.noregon.com.

PC Based Applications

  • Universal Allison DOC®(Diagnostic Optimized Connection) v11.0.1 for Allison DOC® For PC-Service Tool (Please refer to the SIL 16-TR-12 (or Service Tip #1612 on the internet) on the Allison Transmission Extranet.)  Now available from Noregon Systems!    
  • Universal Allison DOC® (Diagnostic Optimized Connection) v11.0.1 for Allison DOC® For PC (H 40/50 EP)  (Please refer to SIL 16-TR-12 (or Service Tip #1612 on the internet))  Now available from Noregon Systems!
  • Universal Allison DOC® v11.0.1 (Allison DOC® For Fleets (1000/2000))  Now available from Noregon Systems!    
  • Universal Allison DOC® v11.0.1 (Allison DOC® For Fleets (3000/4000))  Now available from Noregon Systems!    

Allison DOC® For Fleets is a functional subset of the Allison DOC® For PC-Service Tool.  Allison DOC® For Fleets does not include ECU/TCM Reprogramming, Strip Chart, Action Request Items, Graphics Monitor and a few other items found specifically for the Allison DOC® For PC-Service Tool.  While Allison DOC® For PC-Service Tool was created to be the "essential-rated" diagnostic tool for the Allison Transmission Service Channel providing comprehensive diagnostics and reprogramming capabilities for the technician, Allison DOC® For Fleets is target for truck fleets, municipalities, and/or anyone else who has an interest in fundamental diagnostics for Allison electronically controlled transmissions.  Two versions of Allison DOC® For Fleets are available, Allison DOC® For Fleets (1000/2000) and Allison DOC® For Fleets (3000/4000).

Allison DOC® For PC - Service Tool  Allison DOC® For Fleets
Demo Mode
Diagnostic Trouble Codes View
  Diagnostic Data Monitor
  Calibration Information
  Record Snapshots
  Playback Snapshots
  DTC - Troubleshooting Manual Links
  Performance Complaints
  TRANSHEALTHTM Monitor
  Print Reports
  Training Videos
  User's Guide
  Engineering Calculations
Reprogramming   
 TRANSHEALTHTM Reports  
Custom Data Monitor   Not Available
Graphics Monitor  in
 Strip Chart Allison DOC® for Fleets
 Hydraulic Schematics  
 ATD Calc  
 Data Bus Viewer  
 Action Requests - All  Action Requests - Limited*

 * Allison DOC® For Fleets Action Requests are limited to the following: Reset Adaptive Shift Parameters/Reset Unadapted Shifts, Read Static Data, Reset Prognostic Information {MY09 (and later) Allison 4th Generation Controls and Allison 5th Generation Controls (with 'Prognostics' enabled in the Calibration)}, and Engineering Calculations

Please refer to the table below for general information about applications, versions, product line supported, platform, and Essential Tool status.

Application Version Product Line/Control System Supported  Platform Essential
Universal Allison DOC® (Allison DOC® For PC-Service Tool) 11.0.1  1000, 2000, 3000, 4000 Product Families (including Allison 4th Generation Controls), 5610, 6610, 8610, 9610, 9810 Series Transmissions, 5000, 6000, 8000, 9000 Series Transmissions and MT(B)600 Series, CL(B)T, V, HT(B)700 Series Transmissions Windows® XP® Professional, Windows® Vista® Home Basic (or better), or Windows® 7  Yes
Universal Allison DOC® (Allison DOC® For PC (H 40/50 EP)) 11.0.1 Allison H 40/50 EP System Windows® XP® Professional, Windows® Vista® Home Basic (or better), or Windows® 7 Yes
Universal Allison DOC® (Allison DOC® For Fleets (1000/2000)) 11.0.1 1000 and 2000 Product Families Transmissions (Pre-Allison 4th Generation Controls) and Allison 4th and 5th Generation Controls Windows® XP® Professional,  Windows® Vista® Home Basic (or better), or Windows® 7 No
Universal Allison DOC® (Allison DOC® For Fleets (3000/4000)) 11.0.1 3000 and 4000 Product Families Transmissions with either WTEC II, WTEC III, or Allison 4th and 5th Generation Controls amd CEC3 Off Highway Controls Windows® XP® Professional,  Windows® Vista® Home Basic (or better), or Windows® 7 No